Skip to main content

Table 1 Left ventricular echocardiographic measurements

From: Adverse transverse-tubule remodeling in a rat model of heart failure is attenuated with low-dose triiodothyronine treatment

 ShamMI + VehMI + T3
Heart Rate (bpm)300 ± 31304 ± 26348 ± 77
Ejection Fraction (%)82 ± 443 ± 8*50 ± 5*#
Left Atrial Diameter (mm)3.70 ± 0.495.21 ± 1.22*4.68 ± 1.69
LV End Systolic Volume (cm3)0.15 ± 0.051.42 ± 0.39*1.17 ± 0.36*
LV End Diastolic Volume (cm3)0.83 ± 0.182.44 ± 0.38*2.32 ± 0.63*
Anterior wall thickness systole (mm)2.00 ± 0.220.84 ± 0.17*1.12 ± 0.33*#
Anterior wall thickness diastole (mm)1.16 ± 0.070.76 ± 0.17*0.88 ± 0.19*
Posterior wall thickness systole (mm)2.08 ± 0.192.05 ± 0.132.11 ± 0.11
Posterior wall thickness diastole (mm)1.15 ± 0.061.17 ± 0.051.20 ± 0.07
  1. Values are mean ± SD. MI, myocardial infarction; Veh, vehicle; T3, triiodothyronine. Sham, n = 11; MI + Veh, n = 11; MI + T3, n = 10. One-way ANOVA, post-hoc Tukey’s multiple group comparisons. *p < 0.05 vs sham, #p < 0.05 vs MI + Veh